Epson RC90 Manual page 171

Robot controller
Hide thumbs Also See for RC90:
Table of Contents

Advertisement

No.
Message
3241
Parity was not specified.
3242
Terminator was not specified.
3243
Hardware flow was not specified.
3244
Software flow was not specified.
3245
None was not specified.
Parameter ' O ' or ' C ' was not
3246
specified.
NumAxes parameter was not
3247
specified.
3248
J4Flag value (0-1) was not specified.
J6Flag value (0-127) was not
3249
specified.
3250
Array variable was not specified.
String Array variable was not
3251
specified.
3252
Device ID was not specified.
3253
I/O type was not specified.
RC90 (EPSON RC+ 7.0) Rev.8
Remedy
Parity is not specified in SetCom
statement. Refer to SPEL+ Language
Reference "SetCom Statement" and
specify a proper parity.
Terminator (end of send/receive line) is
not specified in SetCom and SetNet
statements. Refer to SPEL+ Language
Reference "SetCom Statement" and
specify a proper terminator.
Hardware flow is not specified in
SetCom statement. Refer to SPEL+
Language Reference "SetCom
Statement" and specify a proper flow
control.
Software flow is not specified in SetCom
statement. Refer to SPEL+ Language
Reference "SetCom Statement" and
specify a proper flow control.
"NONE" is not specified for software
flow control setting in SetNet statement.
Specify "NONE".
Open or close parameter for the end of a
curve is not specified in Curve statement.
Refer to SPEL+ Language Reference
"Curve Statement" and specify a proper
open/close parameter.
The number of coordinate axes
controlled during a curve motion is not
specified in Curve statement. Refer to
SPEL+ Language Reference "Curve
Statement" and specify a proper number
of the coordinate axes.
Specify 0 or 1, or an expression for
J4Flag value.
Specify an integer from 0 to 127, or an
expression for J6Flag value.
Array variable is not specified in the
statement that requires specification of
array variable. Specify a valid array
variable.
Array which stores a token must be a
string array variable in ParseStr
statement and ParseStr function.
Specify a string array variable.
Device ID is not specified in DispDev
statement or Cls command. Refer to
SPEL+ Language Reference "DispDev
Statement" and specify a proper device
ID.
I/O type is not specified in
IOLabel$ function. Refer to SPEL+
Language Reference
"IOLabel$ Function" and specify a
proper I/O type.
Maintenance 9. Troubleshooting
Note 1
Note 2
155