Epson RC90 Manual page 174

Robot controller
Hide thumbs Also See for RC90:
Table of Contents

Advertisement

Maintenance 9. Troubleshooting
No.
Message
3280
StartPosition was not specified.
3281
TextAlign was not specified.
3282
TextAlign was not specified.
3283
TextAlign was not specified.
3284
WindowState was not specified.
3285
J1FLAG was not specified.
3286
J2FLAG was not specified.
3287
robotID was not specified.
3288
robotID/All was not specified.
3289
areaID was not specified.
3290
File number was not specified.
3292
Database type was not specified.
158
Remedy
StartPosition property setting value is not
specified in GSet statement. Refer to
GUI Builder 7.0 manual "StartPosition
Property" and specify a proper setting
value.
TextAlign property setting value is not
specified in GSet statement.
This error occurs when the control type
cannot be identified because the control
is specified by a string variable. Refer
to GUI Builder 7.0 manual "TextAlign
Property" and specify a proper setting
value.
TextAlign property setting value is not
specified in GSet statement.
This error occurs when the control is a
text box. Refer to GUI Builder 7.0
manual "TextAlign Property" and
specify a proper setting value.
TextAlign property setting value is not
specified in GSet statement.
This error occurs when the control is
other than a text box. Refer to GUI
Builder 7.0 manual "TextAlign Property"
and specify a proper setting value.
WindowState property setting value is
not specified in GSet statement.
Refer to GUI Builder 7.0 manual
"WindowState Property" and specify a
proper setting value.
Specify 0 or 1, or an expression for
J1Flag value.
Specify 0 or 1, or an expression for
J2Flag value.
Specify a robot number.
Robot number or All is not specified in
InsideBox and InsidePlane function.
Specify a robot number which performs
intrusion detection, or All.
Area number is not specified in
InsideBox and InsidePlane function.
Specify an approach check area number
which returns status by an integer from 1
to 15.
File number is not specified in the
command related to file management.
Specify a file number by an integer from
30 to 63 or an expression.
Database type is not specified in
OpenDB statement. Refer to SPEL+
Language Reference "OpenDB
Statement" and specify a proper database
type.
Note 1
RC90 (EPSON RC+ 7.0) Rev.8
Note 2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc90-b

Table of Contents