Predefined user roles
network-admin
mdc-admin
Usage guidelines
If PI power management is disabled, the PSE does not supply power to new PDs when PSE power
overload occurs.
If PI power management is enabled, when a PSE is overloaded, the PSE allocates power to new
PDs based on the priority of their PIs.
This command is only available for the default MDC. For more information about MDCs, see Virtual
Technologies Configuration Guide.
Examples
# Enable PI power management.
<Sysname> system-view
[Sysname] poe pd-policy priority
Related commands
poe priority

poe power max-value

Use poe power max-value to set the maximum PoE power.
Use undo poe power max-value to restore the default.
Syntax
In standalone mode:
poe power max-value max-power
undo poe power max-value
In IRF mode:
poe power chassis chassis-number max-value max-power
undo poe power chassis chassis-number max-value
Default
The maximum power of the power supply is the total maximum power of all operating PoE power
modules in the PoE power frame.
Views
System view
Predefined user roles
network-admin
mdc-admin
Parameters
max-power: Sets the maximum power to a positive integer that is smaller than the total maximum
power of all operating PoE power modules in the PoE power frame. To accommodate transient peak
power surges, the actual maximum power available is 5% higher than the configured maximum
power.
chassis chassis-number: Specifies an IRF member device by its member ID. (In IRF mode.)