HPE FlexNetwork 7500 Series Network Management And Monitoring Command Reference page 402

Hide thumbs Also See for FlexNetwork 7500 Series:
Table of Contents

Advertisement

In IRF mode:
diagnostic monitor interval chassis chassis-number slot slot-number-list [ test test-name ] time
time
undo diagnostic monitor interval chassis chassis-number slot slot-number-list [ test test-name ]
Default
The default execution interval varies by monitoring diagnostic test. To view the execution interval of
diagnostic tests, use the display diagnostic content command.
Views
System view
Predefined user roles
network-admin
Parameters
slot slot-number-list: Specifies a space-separated list of up to seven slot number items. Each item
specifies a card by its slot number or a range of cards in the form of start-slot-number to
end-slot-number. (In standalone mode.)
chassis chassis-number slot slot-number-list: Specifies cards on an IRF member device. The
chassis-number argument represents the member ID of the IRF member device. The
slot-number-list argument specifies a space-separated list of up to seven slot number items. An item
specifies a card by its slot number, a range of cards in the form of start-slot-number to
end-slot-number, by its virtual slot number. The end slot number must be equal to or greater than the
start slot number. (In IRF mode.)
test test-name: Specifies a test by its name, a case-insensitive string of 1 to 31 characters. If you do
not specify this option, the command applies to all monitoring diagnostic tests on the specified cards.
time: Sets an execution interval in the form of hh:mm:ss. The value range for the hh argument is 0 to
23. The value range for the mm and ss arguments is both 0 to 59. If you specify only the hh argument,
you can omit the mm and ss segments. If you specify only the hh and mm arguments, you can omit
the ss segment. For example, to specify 01:00:00, you can enter 1.
Usage guidelines
Use this command to configure the interval at which the system automatically executes enabled
monitoring diagnostic tests.
The configured interval cannot be smaller than the minimum execution interval of the tests. Use the
display diagnostic content verbose command to view the minimum execution interval of the tests.
Examples
# (In standalone mode.) Set the execution interval to 1 minute for test HGMonitor on card 1.
<Sysname> system-view.
[Sysname] diagnostic monitor interval slot 1 test HGMonitor time 00:01:00
# (In IRF mode.) Set the execution interval to 1 minute for test HGMonitor on card 1 of IRF member
device 2.
<Sysname> system-view
[Sysname] diagnostic monitor interval chassis 2 slot 1 test HGMonitor time 00:01:00
Related commands
diagnostic monitor enable
display diagnostic content