Main Motor Error - Xerox Phaser 6180 Service Manual

Color
Hide thumbs Also See for Phaser 6180:
Table of Contents

Advertisement

Error Messages and Codes

Main Motor Error

Applicable Chain Link
Initial Actions
3-84
The Main Motor has failed.
Chain Link
042-325: Main Motor Error
Cycle printer power.
If the problem persists, follow the procedure below.
Troubleshooting Reference Table
Applicable Parts
MCU Board, PL9.1.20
Right Side Harness, PL10.1.15
Main Drive, PL8.1.2
Troubleshooting Procedure Table
Step
Actions and Questions
Check the Transfer Unit, Fuser, and
1
Black Print Cartridge for correct
installation.
Are the parts seated correctly?
Does the error still occur?
2
3
Check the wiring harness connectors
P/J21 and P/J211 between the MCU
Board and the Main Drive. Are the
connectors securely connected?
4
Does the error still occur?
5
Perform the Main Motor test
(page
4-40): Service Mode > Engine
Diag > Motor Test
During the test, close the Front Cover.
Does the Motor operate properly?
6
Check the Main Drive for correct
installation. Is the Main Drive securely
installed?
Does the error still occur?
7
Wiring and Plug/Jack Map References
"Map 1 - Electrical and Drive" on
page 10-10
"Map 4 - LVPS and MCU Board" on
page 10-13
"Main Drive" on page 10-34
Yes
Go to step 3.
Go to step 3.
Go to step 5.
Go to step 5.
Replace the
MCU Board
>
Main
Motor.
(page 8-87).
Go to step 7.
Go to step 8.
Phaser 6180 Color Laser Printer Service Manual
No
Reseat the
Transfer Unit,
Fuser, and Black
Print Cartridge.
Go to step 2.
Complete.
Reconnect the
connectors. Go
to step 4.
Complete.
Go to step 6.
Reseat the Main
Drive. Go to
step 7.
Complete.

Advertisement

Table of Contents
loading