Sub Motor Error - Xerox Phaser 6180 Service Manual

Color
Hide thumbs Also See for Phaser 6180:
Table of Contents

Advertisement

Error Messages and Codes

Sub Motor Error

Applicable Chain Link
Initial Actions
3-86
The Sub Motor has failed.
Chain Link
042-326: Sub Motor Error
Cycle printer power.
If the problem persists, follow the procedure below.
Troubleshooting Reference Table
Applicable Parts
MCU Board, PL9.1.20
Right Side Harness, PL10.1.15
Main Drive, PL8.1.2
Troubleshooting Procedure Table
Step
Actions and Questions
Check the Print Cartridges for correct
1
installation. Are the Print Cartridges
correctly installed?
Does the error still occur?
2
Check the wiring harness connectors
3
P/J22 and P/J221 between the MCU
Board and the Main Drive. Are the
connectors securely connected?
Perform the Sub Motor test
4
(page 4-41):
Service Mode
Diag
>
Motor Test
During the test, close the Front Cover.
Does the Motor operate properly?
Check the Main Drive for correct
5
installation. Is the Main Drive correctly
installed?
6
Does the error still occur?
Wiring and Plug/Jack Map References
"Map 1 - Electrical and Drive" on
page 10-10
"Map 4 - LVPS and MCU Board" on
page 10-13
"Main Drive" on page 10-34
Yes
Go to step 3.
Go to step 3.
Go to step 4.
Replace the
>
Engine
MCU Board
>
Sub
Motor.
(page 8-87).
Go to step 6.
Go to step 7.
Phaser 6180 Color Laser Printer Service Manual
No
Reseat the Print
Cartridges. Go
to step 2.
Complete.
Reconnect the
connectors. Go
to step 4.
Go to step 5.
Reseat the Main
Drive. Go to
step 6.
Complete.

Advertisement