Ricoh MP C2504 Field Service Manual page 1354

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

1-126-013 Set TimeA: Div 3
1-126-014 Set TimeA: Div 4
1-126-021 Delay Time: Div 1
1-126-022 Delay Time: Div 2
1-126-023 Delay Time: Div 3
1-126-024 Delay Time: Div 4
1127
[Energy Saving PprFeed Judgment]
1-127-001 Judging Method Change
1-127-002 Temp.: Threshold: Press
1-127-003 Temp.: Threshold: Atmosphere
1-127-004 Power Supply Voltage: Lower
1-127-005 Power Supply Voltage: Upper
1-127-006 Judgment Time-Out
*ENG [0 to 10000 / * / 1msec/step]
*NA: 1900, EU: 2500, Asia: 2500,
CHN: 2500, TWN: 1900, KOR: 2500
*ENG [0 to 10000 / * / 1msec/step]
*NA: 1100, EU: 1500, Asia: 1500,
CHN: 1500, TWN: 1100, KOR: 1500
*ENG [0 to 10000 / * / 1msec/step]
*NA: 1100, EU: 1500, Asia: 1500,
CHN: 1500, TWN: 1100, KOR: 1500
*ENG [0 to 10000 / * / 1msec/step]
*NA: 1600, EU: 2200, Asia: 2200,
CHN: 2200, TWN: 1600, KOR: 2200
*ENG [0 to 10000 / * / 1msec/step]
*NA: 1900, EU: 2500, Asia: 2500,
CHN: 2500, TWN: 1900, KOR: 2500
*ENG [0 to 10000 / * / 1msec/step]
*NA: 1100, EU: 1500, Asia: 1500,
CHN: 1500, TWN: 1100, KOR: 1500
ENG
[0 to 2 / 1 / 1/step]
ENG
[0 to 200 / 50 / 1deg/step]
ENG
[0 to 200 / 60 / 1deg/step]
ENG
[0 to 300 / * / 1V/step]
*NA: 108, EU: 206, Asia: 206, CHN:
206, TWN: 102 , KOR: 206
ENG
[0 to 300 / * / 1V/step]
*NA: 134, EU: 252, Asia: 252, CHN:
252, TWN: 121 , KOR: 252
ENG
[0 to 10.0 / 10.0 / 0.1sec/step]
Engine SP Tables - SP1000-1
119

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp c2004D243D244