Determine Which Hard Drive Is Faulty
"Verify a Hard Drive" on page 94
■
Determine Which Hard Drive Is Faulty
The following LEDs are lit when a hard drive fault is detected:
System Service Required LEDs on the front panel and rear I/O module
■
Service Required LED on the faulty drive
■
1.
Determine if the System Service Required LEDs are lit on the front panel or the
rear I/O module.
See
"Interpreting LEDs" on page
2.
From the front of the server, check the drive LEDs to identify which drive needs
to be replaced.
See
"Hard Drive LEDs" on page
that needs to be replaced.
3.
Remove the faulty drive.
See
"Remove a Hard Drive" on page
Related Information
"Hard Drive Configuration" on page 87
■
"Hard Drive LEDs" on page 89
■
"Remove a Hard Drive" on page 90
■
"Install a Hard Drive" on page 93
■
"Verify a Hard Drive" on page 94
■
Remove a Hard Drive
Hard drives are hot-service components that can be replaced by customers. For the location of
the hard drives, see
Caution -
discharge. This discharge can cause failure of server components.
1.
Locate the drive in the server that you want to remove.
90
SPARC T8-4 Server Service Manual • January 2022
27.
89. The amber Service Required LED is lit on the drive
"Hard Drive Configuration" on page
This procedure requires that you handle components that are sensitive to electrostatic
90.
87.