Determine If The Main Module Is Faulty; Remove The Main Module - Oracle SPARC T8-4 Service Manual

Hide thumbs Also See for SPARC T8-4:
Table of Contents

Advertisement

No.
LED
Related Information
"Determine if the Main Module Is Faulty" on page 99
"Remove the Main Module" on page 99
"Install the Main Module" on page 102

Determine if the Main Module Is Faulty

Check the Service Required LED on the main module.
The Service Required LED is lit when the server detects a main module fault.
Related Information
"Main Module LEDs" on page 98
"Remove the Main Module" on page 99
"Install the Main Module" on page 102

Remove the Main Module

1.
(Optional) If you are replacing a faulty main module, you must back up ILOM
configuration settings.
a.
Configure the SER MGT port to enable the configuration parameters to be
uploaded.
Refer to the ILOM documentation for network configuration instructions.
Back up the ILOM configuration parameters.
b.
Refer to the
2.
Ensure that the server is powered off. Power off the server.
See
"Removing Power From the Server" on page
Icon
Description
■ Steady on, green – SPM is running in its normal operating state. No
service actions are required.
■ Blink, green – SPM is initializing the Oracle ILOM firmware.
■ Steady on, amber – A SPM error has occurred and service is
required.
ILOM documentation
(http://www.oracle.com/goto/ilom/docs).
Determine if the Main Module Is Faulty
50.
Servicing the Main Module
99