Powering Down A Call Server - Splicecom S8000/718 Installation & Maintenance Manual

Maximiser
Table of Contents

Advertisement

Installation and Maintenance Manual
3
The SpliceCom LED will flash once, flash again after 2 seconds and then turn off for 10 seconds.
4
Wait for the LED to be on solid again to indicate that the system has restarted successfully.
If you need to default the database but you cannot perform an orderly shut because, for example, the
SpliceCom LED is flashing 5 seconds on and 5 seconds off since the Call Server is acting as a DHCP client
and cannot find a DHCP server, press the Reset Switch while powering off and then on the Call Server.
Once the SpliceCom LED is flashing press the Reset Switch 4 times.
Upgrading the Software on a Module
The software for the Phone and Trunk Module is stored on the Call Server. Upgrade these modules as
follows: (Ensure you have a LAN connection to the Call Server). For further information please refer to
page 286.
1
Firstly perform an orderly shut down on the Phone or Trunk module
2
When the SpliceCom LED is flashing press the Reset Switch 8 times (or no more than 10 times)
3
The LED will flash twice, flash twice again after 2 seconds and then turn off.
4
The activity LED on the LAN port will go solid for a few seconds as the software is downloaded.
5
Shortly after the Splicecom LED will be on and the unit will register with the system again. Each port
will flash the ring LED.
The software on the Call Server is upgraded via a Factory Restart or via software patch as detailed from
page 286. However if you accidentally press the Reset Switch 8 times on a Call Server no action will be
performed.
Reset Switch Summary
The following table gives a summary of the functionality of the Reset Switch after an orderly shut down.
No of presses
Min
Max
1
3
Reboot
4
7
Default the database
8
10
Upgrade software.(Not
Call Server).
11
n/a
Total Erase
(SpliceCom use only)
12+
n/a
Abort command and
perform reboot

Powering down a Call Server

It is important to shut down the file system within the Call Server before removing power.
1
On the Call Server press the Reset Switch once.
282
Function
LED will go off, wait 10 secs, then flash rapidly during
restart
LED will flash one, repeat after 2 secs, then go off.
Wait for system to come back up, LED on solid.
LED will flash twice, repeat after 2 secs, then go off.
Watch LAN activity LED for download.
NOT TO BE DONE BY ANYONE OTHER THAN
SPLICECOM PERSONNEL. THIS WILL RENDER THE UNIT
INOPERABLE.
LED Indicator
Maintenance & Troubleshooting
Installation and Maintenance Manual v4/0615/10