Resetting The Error Status After Replacing Cpus - Fujitsu PRIMERGY TX1330 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX1330 M4:
Table of Contents

Advertisement

Basic software procedures
▶ Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
Using Infrastructure Manager
The status of server (node) which failed memory module is installed becomes
error.
When replacing the memory module, the status will be updated after getting
information manually or automatically updated daily.
Proceed as follows to get node information with Infrastructure Manager:
▶ Start up the GUI of the Infrastructure Manager and login.
▶ Display the node list from menu (manage > node).
▶ Select the target node and display the detail screen.
▶ Execute getting node information from action menu.
5.3.7.2

Resetting the error status after replacing CPUs

In case of a CPU error, an error counter may be set for the defective CPU.
Important note
After replacing a defective CPU, the error counter must be reset
manually using one of the methods below.
Using ServerView Maintenance Tools (Windows only)
▶ Launch the ServerView Maintenance Tools:
Start > Apps > Fujitsu > Maintenance Tools
▶ Choose the CPU status tab.
▶ Select the CPU which shows the pre-failure status.
▶ Click on Reset Status.
▶ Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
112
Upgrade and Maintenance Manual
TX1330 M4