Basic software procedures
Ê If more than one server is managed in SVOM, select the target server and
click Next.
Ê From the Server Configuration menu pane, choose Restart Options.
Ê Under Reboot Retries, specify the maximum number of boot attempts (0 to 7)
in the Default for reboot tries field.
Resetting the boot retry counter using iRMC web frontend
Ê Enter the ServerView iRMC web frontend.
Ê Select the Server Management menu.
Ê The following boot retry counter settings are available under ASR&R Options:
Ê Under Retry counter max specify the maximum number of attempts to boot
the operating system (0 to 7).
Ê Under Retry counter the current number of remaining boot attempts is
displayed. Overwrite this value with the maximum number of boot
attempts specified above in order to reset the boot retry counter.
Ê Click Apply for the changes to take effect.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
5.2.7
Resetting the error status after replacing memory
modules or processors
5.2.7.1

Memory modules

ServerView Operations Manager may report a defective memory module in
case of a memory error.
I
Important note
After replacing a defective memory module, please check if the error
counter has been reset automatically. If the memory slot is still marked
as failed, please reset the error counter manually using one of the
methods below.
Using the iRMC web frontend
Ê Enter the ServerView iRMC web frontend.