Honda CBR125R Owner's Manual page 156

Table of Contents

Advertisement

FUEL SYSTEM (PGM-FI)
Install the bank angle sensor, collars and mounting
Install the bank
screw/washers.
angle sensor with
Tighten the mounting screws to the specified
its "UP" mark
torque.
facing up.
TORQUE: 1.2 N·m (0.1 kgf·m, 0.9 lbf·ft)
Install the upper cowl (page 2-10).
INSPECTION WITH HDS POCKET
TESTER
Connect the HDS pocket tester (page 5-11).
Remove the bank angle sensor (page 5-63).
Connect the bank angle sensor 3P connector.
Place the bank angle sensor horizontal as shown.
Turn the ignition switch ON (and engine stop switch
" ": CM and U type).
Read the voltage with the HDS pocket tester.
Standard: 3.6 – 4.4 V
Incline the bank angle sensor approximately 60° to
the left or right with keeping the ignition switch ON
(and engine stop switch " ": CM and U type).
Read the voltage with HDS pocket tester.
Standard: 0.7 – 1.3 V
• If you repeat this test, first turn the ignition
switch OFF, then turn the ignition switch ON (and
engine stop switch " ": CM and U type).
5-64
"UP" MARK
60° BANK ANGLE POSITION
(approximately) 60 °
HORIZONTAL
60 ° (approximately)

Advertisement

Table of Contents
loading