Honda CBR125R Owner's Manual page 124

Table of Contents

Advertisement

FUEL SYSTEM (PGM-FI)
2. Bank Angle
Inspection
Turn the ignition switch OFF.
Disconnect the bank angle sensor 3P connector.
Turn the ignition switch ON (and engine stop
switch " ": CM and U type).
Measure the voltage at the bank angle sensor
connector of the wire side.
Connection: White/red (+) – Green/orange (–)
Standard:
Is there within 4.75 – 5.25 V?
YES
NO
3. Bank Angle Sensor Input Voltage Line Open
Circuit Inspection
Turn the ignition switch OFF.
Disconnect the ECM 33P connector.
Check the continuities between the ECM 33P and
bank angle sensor 3P connectors.
Connection: 6 (White/red) – White/red
TOOL:
Test probe
Are there continuities?
YES
NO
4. Bank Angle Sensor Output Line Open Circuit
Inspection
Turn the ignition switch OFF.
Disconnect the ECM 33P connector.
Check the continuity between the ECM 33P and
bank angle sensor 3P connectors.
Connection: 26 (Red/blue) – Red/blue
TOOL:
Test probe
Is there continuity?
YES
NO
5-32
Sensor
Power Input
4.75 – 5.25 V
– GO TO STEP 4.
– GO TO STEP 3.
4 (Green/orange) – Green/orange
07ZAJ-RDJA110
– Replace the ECM with a known good
one, and recheck.
– • Open circuit in White/red wire
• Open circuit in Green/orange wire
07ZAJ-RDJA110
– Inspect the bank angle sensor (page 5-
64).
– Open circuit in Red/blue wire
Voltage
BANK ANGLE SENSOR 3P CONNECTOR
(Wire side/female terminals)
W/R
BANK ANGLE SENSOR 3P CONNECTOR
(Wire side/female terminals)
G/O
W/R
BANK ANGLE SENSOR 3P CONNECTOR
(Wire side/female terminal)
R/Bu
G/O
(4)
(6)
ECM 33P CONNECTOR
(Wire side/female terminals)
(26)
ECM 33P CONNECTOR
(Wire side/female terminal)

Advertisement

Table of Contents
loading