INSPECTION WITH ECM TEST
HARNESS
Connect the ECM test harness (page 5-11).
Remove the bank angle sensor (page 5-63).
Connect the bank angle sensor 3P connector.
Place the bank angle sensor horizontal as shown.
Turn the ignition switch ON (and engine stop switch
" ": CM and U type).
Measure the output voltage with the ECM test har-
ness at its terminals.
Connection: 26 (+) – 4 (–)
Standard:
Incline the bank angle sensor approximately 60° to
the left or right with keeping the ignition switch ON
(and engine stop switch " ": CM and U type).
Measure the output voltage with ECM test harness
at its terminals.
Connection: 26 (+) – 4 (–)
Standard:
• If you repeat this test, first turn the ignition
switch OFF, then turn the ignition switch ON (and
engine stop switch " ": CM and U type).

ECM

REMOVAL/ INSTALLATION
Lift and support the fuel tank (page 3-6).
Open the rubber sheet (page 6-10).
Turn the ignition switch OFF.
Disconnect the ECM 33P connector.
Remove the rubber holder and ECM.
Remove the ECM from the rubber holder.
Install the ECM to the rubber holder install them to
the frame.
Connect the ECM 33P connector.
Close the rubber sheet (page 6-15).
Remove the suitable support and close the fuel tank
(page 3-6).
3.6 – 4.4 V
0.7 – 1.3 V
FUEL SYSTEM (PGM-FI)
(4)
(26)
60° BANK ANGLE POSITION
(approximately) 60 °
HORIZONTAL
ECM
ECM 33P CONNECTOR
RUBBER HOLDER
60 ° (approximately)
5-65