REPLACEMENT AND ADJUSTMENT

3.5.2 UPPER TRAY PAPER LIMIT AND EXIT SENSOR

[A]

Upper Tray Paper Limit Sensor

1. Remove the top cover.
2. Remove the sensor cover [A] ( x 2).
3. Remove the sensor bracket [B] ( x 1).
4. Replace the upper tray paper limit sensor [C] ( x 1).

Upper Tray Exit Sensor

5. Remove the sensor bracket [D] ( x 1).
6. Replace the upper tray exit sensor [E] ( x 1).
B706
CÓPIA NÃO CONTROLADA
[B]
[C]
12
CÓPIA NÃO CONTROLADA
[D]
[E]
B706R510.WMF