Fisher 67D Series Instruction Manual

Fisher 67D Series Instruction Manual

Pressure reducing regulators

Advertisement

Quick Links

Instruction Manual
D103151X012
April 2017
67D Series Pressure Reducing Regulators
TyPe 67D oR 67DR RegulaToR
!
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion,
fire and/or chemical contamination
causing property damage and personal
injury or death.
Fisher™ regulators must be
installed, operated and maintained
in accordance with federal, state and
local codes, rules and regulations and
emerson Process Management Regulator
Technologies, inc. instructions.
if the regulator vents gas or a leak
develops in the system, service to
the unit may be required. Failure
to correct trouble could result in a
hazardous condition.
Figure 1. 67D Series Pressure Reducing Regulators
WaRning
TyPe 67DF oR 67DFR FilTeReD RegulaToR
installation, operation and maintenance
procedures performed by unqualified
personnel may result in improper
adjustment and unsafe operation. either
condition may result in equipment
damage or personal injury. use qualified
personnel when installing, operating
and maintaining the 67D Series Pressure
Reducing Regulators.
introduction
Scope of the Manual
This manual provides instructions for the installation,
maintenance and parts ordering information for
67D Series regulators. Instructions and parts lists for
other equipment mentioned in this instruction manual,
as well as for other 67 Series regulators, are found in
separate manuals.
67D Series

Advertisement

Table of Contents
loading

Summary of Contents for Fisher 67D Series

  • Page 1 67D Series regulators. Instructions and parts lists for the unit may be required. Failure other equipment mentioned in this instruction manual,...
  • Page 2: Specifications

    67D Series Specifications This section lists the specifications for the 67D Series regulators. Factory specification such as type, maximum inlet pressure and outlet pressure are stamped on the nameplate fastened on the regulator at the factory. available Configurations Temperature Capabilities...
  • Page 3: Principle Of Operation

    Product Descriptions internal Relief (Types 67DR, 67DSR, ATMOSPHERIC PRESSURE 67DFR and 67DFSR) LOADING PRESSURE The 67D Series direct-operated regulators are typically INTERMEDIATE PRESSURE used to provide constantly controlled, reduced pressures. If for some reason, outside of normal operating PILOT SUPPLY PRESSURE They are suitable for most air or gas applications.
  • Page 4: Installation

    67D Series Table 1. Outlet Pressure Ranges and Control Spring Data ConTRol SPRing DaTa ouTleT PReSSuRe RangeS TyPe Wire Diameter Free length Part number Color Material psig 0 to 20 0 to 1.4 GE07809T012 Green stripe 0.135 3.43 1.43 36.2 0 to 35 0 to 2.4...
  • Page 5: Overpressure Protection

    Protection Shutdown The 67D Series regulators have maximum outlet First, close the nearest upstream block valve and pressure ratings that are lower than their maximum then close the nearest downstream block valve inlet pressure ratings.
  • Page 6 67D Series 4. Place the diaphragm assembly (key 16) on the WaRning body (key 1) as shown in Figure 3 or 4. Push down on the diaphragm assembly to make sure To avoid personal injury, property the valve plug (key 57) strokes smoothly and damage or equipment damage caused approximately 1/16 in.
  • Page 7: Parts Ordering

    67D Series Replace part if damaged. The valve stem may be 7. When all maintenance is complete, refer to the cleaned or replaced. If the soft seat (key 15) was Startup and Adjustment section to put the regulator removed, make sure it is properly snapped into back into operation and adjust the pressure place before installing the valve stem.
  • Page 8 67D Series Description Part number Description Part number automatic Drain Conversion Kits (continued) O-ring (Spring Retainer) Types 67DF, 67DFR, 67DFS and 67DFSR (continued) For Type 67D, 67DR, 67DS or 67DSR Types 67DFS and 67DFSR Nitrile (NBR) 10A3803X092 Nitrile (NBR) R67ADNX0022...
  • Page 9 67D Series Description Part number Pressure Gauge (not shown) Triple Scale Pressure Connected Gauge (For Types 67D, 67DR, 67DF and 67DFR) Brass 0 to 30 psig / 0 to 2.1 bar / 0 to 0.2 MPa 11B8579X022 0 to 60 psig / 0 to 4.1 bar / 0 to 0.4 MPa 11B8579X032 0 to 160 psig / 0 to 11.0 bar / 0 to 1.1 MPa...
  • Page 10 67D Series PaRTS noT SHoWn: 25 GE32850_B GE31805_B aPPly luBRiCanT (l) aPPly luBRiCanT (l) Figure 5. Type 67DF or 67DFR Assembly Figure 6. Type 67DFS or 67DFSR Assembly...
  • Page 11 PoSiTion 3 PoSiTion 4 PoSiTion 2 40C1728_A GE31784_C PoSiTion 1 (aligneD WiTH inleT) (STanDaRD) Figure 7. 67D Series Optional Panel Mount Figure 8. 67D Series Spring Case Vent Positions PuSHeR PoST (WiTHouT RelieF) loWeR SPRing SeaT ReTaining Ring DiaPHRagM PlaTe...
  • Page 12 The Emerson logo is a trademark and service mark of Emerson Regulator Technologies Electric Co. All other marks are the property of their prospective owners. Fisher™ is a mark owned by Fisher Controls International LLC, a Americas Asia Pacific business of Emerson Automation Solutions.

Table of Contents