| CFM Commands
C
42
HAPTER
Cross Check Operations
mep crosscheck
mpid
mep-unknown – Sends a trap if an unconfigured MEP comes up.
D
S
EFAULT
ETTING
All continuity checks are enabled.
C
M
OMMAND
ODE
Global Configuration
C
U
OMMAND
SAGE
For this trap type to function, cross-checking must be enabled on the
◆
required maintenance associations using the
crosscheck
command.
A mep-missing trap is sent if cross-checking is enabled (with the
◆
ethernet cfm mep crosscheck
remote MEP configured in the static list (with the
command).
◆
A mep-unknown trap is sent if cross-checking is enabled, and a CCM is
received from a remote MEP that is not configured in the static list.
◆
A ma-up trap is sent if cross-checking is enabled, and a CCM is received
from all remote MEPs configured in the static list for this maintenance
association.
E
XAMPLE
This example enables SNMP traps for mep-unknown events detected in
cross-check operations.
Console(config)#snmp-server enable traps ethernet cfm crosscheck mep-unknown
Console(config)#
This command statically defines a remote MEP in a maintenance
association. Use the no form to remove a remote MEP.
S
YNTAX
[no] mep crosscheck mpid mpid ma ma-name
mpid – Identifier for a maintenance end point which exists on
another CFM-enabled device within the same MA. (Range: 1-8191)
ma-name – Maintenance association name. (Range: 1-43
alphanumeric characters)
D
S
EFAULT
ETTING
No remote MEPs are configured.
C
M
OMMAND
ODE
CFM Domain Configuration
– 1374 –
ethernet cfm mep
command), and no CCM is received for a
mep crosscheck mpid