COMMAND CODE TITLE:
EA
Y
No.
MEANING
6
Fault log/Call log
collection on VoIP
call
NOTE 1 :
Even if the external alarm is set as MN or MJ alarm for system reset (1st data=01), no
alarm is output in the case of Power On, Reset key operated, reset from the PCPro/CAT,
and reset by CPU SENS switch selection.
NOTE 2 :
The External Alarm Kind for "Number of lockout stations was more than predetermined
number" is fixed as MN. In the case of this office data, even if the 2nd data is set to 0/1/2/
3, it simply means the fault information is to be registered into Fault Memory. In this case,
External Alarm Kind cannot be changed.
NOTE 3 :
The fault information of the fault kind No, 02C/03C is also registered to the CPU blade
when the OAI fault occurs/the OAI fault is restored. The OAI fault contents that are regis-
tered to the MP card as follows.
• Fault Kind 02C (LAN application fault occurrence)
(a) ABOUT/RLRQ (U-ABOUT/RLRQ received)
(b) Fault detection by health check (health check IP T.O)
• Fault Kind 03C (LAN application returned to normal condition)
(a) Association is established (AARQ received)
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
1ST DATA
DATA
MEANING
10
Whether fault logs are col-
lected when the IP Sta-
tions login to the system or
the VoIPDB is in online
status
11
Terminals/VoIPDB to col-
lect fault logs
2ND DATA
DATA
0
To collect
1
Not collected
X-
IP Station No.
NOTE 8
XXXXXXXX
DDXXZZZ
XX : Unit No. (01-50)
ZZZ : VoIPDB Channel
3-537
: Default
RELATED
COMMAND
MEANING
No. (001-128)
Continued on next page
NWA-033623-001 Rev.3.0
NOVEMBER/12/2008
CMEA
91ch3008.fm