NEC UNIVERGE SV8300 Command Manual page 44

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

NOTE:
The data setting is as follows.
• When the SENSE switch is set to E (default setting):
RS-232C CONNECTION
Data speed
Data length
Parity
Stop bit length: 2 bits
• When the SENSE switch is set to F:
RS-233 CONNECTION
As per CM40 Y=08
For details, refer to the System Hardware Manual.
(RS1/RS2 port)
: 9600 bps
: 8 bits
: None
(RS1/RS2 port)
METHOD OF SETTING ON-LINE/OFF-LINE MODE
IP CONNECTION
(ETHERNET/VOIP port)
• Maintenance port
Data speed : Auto Negotiation
IP address
: Unit No. 01: 192.168.1.1
Unit No. 02: 192.168.1.2
Unit No. 03: 192.168.1.3
Unit No. 04: 192.168.1.4
Subnet Mask : 255.255.255.0
Default Gateway
PCPro connection port : 60000
• VOIP port
Data speed : Auto Negotiation
IP address
: For Control Packet
Unit No. 01: 172.16.1.1
Unit No. 02: 172.16.2.1
Unit No. 03: 172.16.3.1
Unit No. 04: 172.16.4.1
: For Voice Control
Unit No. 01: 172.16.1.1-9
Unit No. 02: 172.16.2.1-9
Unit No. 03: 172.16.3.1-9
Unit No. 04: 172.16.4.1-9
Subnet Mask : 255.255.255.0
Default Gateway
PCPro connection port : 60000
IP CONNECTION
(ETHERNET/VOIP port)
Same as SENSE switch E
2-7
Chapter 2 PRECAUTION
: None
: None
NWA-033623-001 Rev.3.0
91ch2001.fm
JULY/18/2008

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents