NEC UNIVERGE SV8300 Command Manual page 404

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
64
Y
No.
MEANING
1
Tenant Number for Music
on Hold
NOTE:
The setting data "11" and Hold Tone on CPU blade are effective only when the second data of CM48
Y=0 is set to "1300".
2
Answering System for
Night Mode
NOTE:
When providing a Night Message for Automated Attendant, the second data "08" of CM30 Y=30, 31
cannot be specified for handling of busy/not available Automated Attendant destination.
3
Number of Queue Limit
for TAS, Day Mode
4
Number of Queue Limit
for TAS, Night Mode
5
Number of Queue Limit
for TAS, Mode A
6
Number of Queue Limit
for TAS, Mode B
10
Trunk access code for
call forwarding in
Mobility Access mode
AUTOMATED ATTENDANT, TENANT NUMBER FOR MUSIC ON HOLD, NUMBER
OF QUEUE LIMIT, TRUNK ACCESS CODE FOR MOBILITY ACCESS MODE, ISDN
ALTERNATING ROUTING
TENANT
00-63
NONE
00-63
00-63
NONE
X-XXXX
NONE
SETTING DATA
DATA
MEANING
11
External Hold Tone Source
through Pin JACK on the
CPU blade
Hold Tone Source on CPU
blade
00
DT connection
01
Hold Tone Source on CPU
blade + DT connection
02
Night Message + DT
connection
03
As per CM64 Y=0
01
1 line
99
99 lines
No limit
Trunk Access Code
(1-4 digits)
No data
3-355
CM64
: Default
RELATED
COMMAND
CM48 Y=0
CM30 Y=02, 03
CM41 Y=0>33, 43
CM49 Y=00>02XX,
Y=02
CM64 Y=0
CM51 Y=26, 30
CM76 Y=16
CM51 Y=27, 30
CM76 Y=16
CM51 Y=28, 30
CM76 Y=16
CM51 Y=29, 30
CM76 Y=16
CM15 Y=216
CM76 Y=41
Continued on next page
NWA-033623-001 Rev.3.0
91ch3005.fm
NOVEMBER/12/2008

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents