COMMAND CODE TITLE:
E0
NOTE 1:
For the Data "MMDDHHmm", enter the Month, Date, and Time (hour and minute) of the
time, as shown below.
MM : Month (01 (Jan.)-12 (Dec.))
DD : Date (01-31)
HH : Hour (00-23)
mm : Minute (00-59)
NOTE 2:
Set the same Unit No. and Slot No. assigned by the first data.
NOTE 3:
"00000000-FFFFFFFF" is displayed as the second data when this command is executed.
You can confirm the port status of the blade which is accommodated to the specified slot by
this data display.
00000000: All ports are not in use
Other than 00000000: Ports in use are included.
NOTE 4:
For the blade reset while the system is operating, be sure to check the port status. The blade
reset must be executed when all ports are not in use.
NOTE 5:
Set the CME0 Y=5>00 when setting the new IPT (P2P CCIS) after the IPT (P2P CCIS)
installation (this data cannot be used once the reset has been executed by this data).
NOTE 6:
This data setting has no effect on services other than related to IPT (P2P CCIS) even if the
reset (CME0 Y=5>00) is executed after the IPT (P2P CCIS) installation.
NOTE 7:
Set the CME0 Y=5>01 when changing the commands (CM10 Y=2, CMA7 Y=44, 46, and 50)
which require a reset related to IPT (P2P CCIS).
NOTE 8:
For the reset (CME0 Y=5>01) while the system is operating, the call connected to a line via
IPT (P2P CCIS) is not disconnected.