COMMAND CODE TITLE:
0B
DATA TABLE:
Y=0XX
Y
No.
MEANING
0XX 0 : Maintenance Port
XX: Unit No. (01-50)
LAN DATA ASSIGNMENT
1ST DATA
DATA
MEANING
00
IP Address for the sys-
tem
NOTE 1:
This data cannot be entered by CAT when using 8300R1 software.
NOTE 2:
When setting the IP address by this data, a period (.) must be entered
between the numbers (example: 255.255.255.254).
01
Subnet Mask for the
system
NOTE 1:
This data cannot be entered by CAT when using 8300R1 software.
NOTE 2:
When setting the Subnet Mask by this data, a period (.) must be
entered between the numbers (example: 255.255.255.252).
02
Default Gateway for the
system
NOTE 1:
This data cannot be entered by CAT when using 8300R1 software.
NOTE 2:
When setting the Default Gateway by this data, a period (.) must be en-
tered between the numbers (example: 255.255.255.254).
09
Speed mode for the LAN
Interface
2ND DATA
DATA
XXX.XX
IP Address
...X
(Maximum 15 digits)
XXX.XXX.XXX.XXX=
0.0.0.1-255.255.255.254
NONE
No data
XXX.XX
Subnet Mask
...X
(Maximum 15 digits)
XXX.XXX.XXX.XXX=
255.0.0.0-255.255.255.252
NONE
No data
XXX.XX
Default Gateway
...X
(Maximum 15 digits)
XXX.XXX.XXX.XXX=
0.0.0.1-255.255.255.254
NONE
No data
02
100 Mbps (Full-Duplex)
03
100 Mbps (Half-Duplex)
04
10 Mbps (Full-Duplex)
05
10 Mbps (Half-Duplex)
15
Auto Negotiation
3-76
RESET
: Default
RELATED
COMMAND
MEANING
Continued on next page
NWA-033623-001 Rev.3.0
NOVEMBER/12/2008
CM0B
91ch3001.fm

Hide quick links:

Advertisement

Table of Contents
loading