NEC UNIVERGE SV8300 Command Manual page 417

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
67
Y=10-24
Y
No.
MEANING
10
Time Zone setting
of each location
NOTE 1:
System clock should be assigned by CM02.
NOTE 2:
After changing the data, system data copy to Remote Unit by CMEC Y=8 is required.
LOCATION DATA ASSIGNMENT
1ST DATA
DATA
MEANING
00
Location number
63
2nd Data
A2345
A2330
A2315
A2300
A0100
A0045
A0030
A0015
NONE
B0015
B0030
B0045
B0100
B2300
B2315
B2330
B2345
CCC
2ND DATA
DATA
MEANING
XXXXX
Time Zone
(see the table below)
NONE
No Time Zone
Time Zone
System Clock +23:45
System Clock +23:30
System Clock +23:15
System Clock +23:00
System Clock +01:00
System Clock +00:45
System Clock +00:30
System Clock +00:15
No Time Zone (No time difference)
System Clock -00:15
System Clock -00:30
System Clock -00:45
System Clock -01:00
System Clock -23:00
System Clock -23:15
System Clock -23:30
System Clock -23:45
Time Zone data clear
3-368
CM67
: Default
RELATED
COMMAND
CM02
+15 minutes
increments
-15 minutes
increments
Continued on next page
NWA-033623-001 Rev.3.0
91ch3005.fm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents