NEC UNIVERGE SV8300 Command Manual page 341

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
42
NOTE 1:
Default in the DATA TABLE represents the value for the data "NONE". In this case, the fol-
lowing conversion is performed in the Deluxe Traveling Class Mark-CCIS.
(1) 2400 IPX to SV8300
2400 IPX
TRK RESTRICTION CLASS
0: OG via ATT
1: Unrestricted-1
2: Unrestricted-2
3: Non-Restricted
4: Semi-Restricted
5: Restricted
6: Fully-Restricted
7:
8:
Not Defined
15:
(2) SV8300 to 2400 IPX
SV8300
TRK RESTRICTION CLASS
1: Unrestricted (RCA)
2: Non-Unrestricted-1 (RCB)
3: Non-Restricted-2 (RCC)
4: Semi-Restricted-1 (RCD)
5: Semi-Restricted-2 (RCE)
6: Restricted-1 (RCF)
7: Restricted-2 (RCG)
8: Fully-Restricted (RCH)
NOTE 2:
This command should be used when changing the reset setting shown above, or when receiv-
ing the 2400 IPX Trunk Restriction Class (9-15) as a Deluxe Travelling Class Mark.
TRUNK RESTRICTION CLASS CONVERSION
SV8300
TRK RESTRICTION CLASS
1: Unrestricted (RCA)
1: Unrestricted (RCA)
2: Non-Restricted-1 (RCB)
3: Non-Restricted-2 (RCC)
4: Semi-Restricted-1 (RCD)
5: Semi-Restricted-2 (RCE)
6: Restricted-1 (RCF)
7: Restricted-2 (RCG)
8: Fully-Restricted (RCH)
2400 IPX
TRK RESTRICTION CLASS
1: Unrestricted-1
2: Unrestricted-2
3: Non-Restricted
4: Semi-Restricted
5: Restricted
6: Fully-Restricted
7:
Not Defined
8:
3-292