2.5
EMC Installation Conditions
This section describes the recommended installation conditions that satisfy EMC
guidelines for each model of the SGDV SERVOPACK. The conditions required for
the standard type (base-mounted) of SERVOPACK are described. Refer to this sec-
tion for other SERVOPACK models such as the rack-mounted types as well.
This section describes the EMC installation conditions satisfied in test conditions
prepared by Yaskawa. The actual EMC level may differ depending on the actual sys-
tem's configuration, wiring, and other conditions. However, because this product is
built-in, check that the following conditions are still met after being installed in the
user's product.
The applicable standards are EN55011/A2 group 1 class A, EN61800-3, and
EN61000-6-2.
2.5.1
SGDV-05 (Analog Pulse Model)
Single-phase 100 V, SGDV-F05A ( = R70, R90, 2R1,
2R8)
Power supply:
Single-phase
100 VAC
PE
Symbol
www.dadehpardazan.ir 88594014-15
One turn
Noise
filter
5
Surge
absorber
Two turn
Two turn
Cable Name
I/O signal cable
Cable for safety unit
Linear servomotor main circuit cable
Linear scale connection cables
Main circuit cable
2.5 EMC Installation Conditions
Shield box
SERVOPACK
U, V, W
L1, L2
One turn
L1C, L2C
CN2
CN1
CN8
Core
Core
Two turn
Clamp
1
2
Host
Safety unit
controller
Specification
Shield cable
Shield cable
Shield cable
Shield cable
Shield cable
Brake
Linear
3
servomotor
Linear
scale
4
PE
2-37
2