Making RJ21X Connections (16/24-Port)
The pin assignments for the RJ21X connector are telco standard. Connect
telephone devices from an RJ11 jack field, or a punch down block. Each
line provides a two-wire loop or groundstart connection. To perform the
connection, use a customer-provided cable terminated at one end with an
RJ21X connector. After connecting each color-coded wire pair to the
corresponding telephone connection on the jack field or punchdown block,
connect the RJ21X connector to the connector on the IAD rear panel.
When you have completed the tasks in this chapter, reset the IAD and test
your configuration.
Reset the IAD
Reset the IAD (page 14) to synchronize the physical connections.
Verify Normal Power Up and Operation
Finally, to test your configuration for proper data and voice operation,
perform the operational test