Paradyne JetFusion Integrated Access Device User Manual page 264

Integrated access device
Table of Contents

Advertisement

2000-A2-GB20-10
Table 14–1.Troubleshooting—Symptoms and Causes
Symptom
Cannot receive or send
data
If IAD is configured as
router:
If the IAD is configured
as a bridge:
- 245 -
Probable Cause Corrective Action
Incorrect PVC/DLCI
Verify these settings:
set for data channel
VPI: 0 to 255
VCI: 0 to 65535
DLCI: 16 to 1023
(default PVC 0/38; DLCI
32)
View Interface
(page 193) and Media
statistics (page 205) to
check the pack receive
and send status.
Incorrect network
Check and correct
setup
network setup as
necessary.
Incorrect or missing
Ensure that both the LAN
LAN or WAN IP
and WAN IP addresses
address
are configured.
Incorrect or missing
Review the routing table
default static route
and correct as necessary
(page 217).
Incompatible RIPv1 Check and correct subnet
masks (255.255.255.0)
Update RIPv1 to RIPv2.
incorrect bridging
Review IAD configuration
parameters
(page 182) and current
bridge status (page 218).
Correct as necessary
Incorrect
Ensure that the IAD is
connection
connected to another
bridge
Missing peer or
Install a converter to
converter
convert 1483 cells to
Ethernet packets.
February 2004

Advertisement

Table of Contents
loading

This manual is also suitable for:

2000Jetfusion

Table of Contents