Table B–3. Country Code Settings—Belgium2, Denmark, and Italy
Parameters
Min. Flash Hook (ms)
Max. Flash Hook (ms)
Ring Frequency (Hz)
Receive Gain (dB)
Transmit Gain (dB)
Ref/Input Impedance
(Ohms)
Load Impedance
(Ohms)
2000-A2-GB20-10
Belgium2
90
130
25
0
-7
150 + (830 // 72nF)
600
Ring frequency and impedance settings are automatically
JF2008
JF2104
applied to the JF2008, JF2104 and JF2108.
JF2108
- 253 -
Denmark
90
130
25
0
-6
300 + (1000 // 220nF)
400 + (500 // 330nF)
Italy
90
130
25
0
-7
180 + (630 // 60nF)
0 + (750 // 18nF)