Step 5: Install Reserve Power

Cabinet Floor Mounting

The part numbers and descriptions of the floor mounting hardware are shown in
Table 7-9
Floor Mount Hardware
Option
BCCB120 or
BCCB240
BFIF
Floor Mounting One or Two Cabinets
1. Remove front, side, and top covers from cabinet(s)
from all cabinet back covers using a Phillips screwdriver.
2. Make sure that cabinet power supplies (BPSU672A) are installed per
on
Page
3. If installing just one or two cabinets, install the BFIF fixtures on each side of the bottom of the
cabinet
4. Set the bottom cabinet on the floor or mount surface, then set the top cabinet on the bottom
cabinet.
5. Fasten the two cabinets together with the four screws provided: (two screws at front "A" and
two at back "B" of cabinet. Place cabinet where it should be installed.
6. Connect the Expansion Cabinet data cable to the "CAB. 2" data cable connector on the Base
Cabinet
...or if installing a Remote Expansion Cabinet: see details in
Instructions" on Page
7. Install ground wiring, AC and reserve power cabling, and PCB cabling per the
"Recommended Installation Sequence"
8. Fill out cabinet/slot identification labels on cabinet(s)
9. Reinstall covers on to cabinets
7-30
DK424i conduit connection box that is installed in the base cabinet, side panel. It is used to
hardwire Primary AC power and reserve battery power connections through conduit. These
boxes are required by UL for three or more floor mounted cabinets. Conduit boxes are not
required for wall mounted systems with any number of cabinets or floor mounted system with
one or two cabinets. They can be used as an option on any system.
The BCCB120 is required when connecting AC120VAC as the primary power source and the
BCCB240 is required when connecting AC208VAC or AC240VAC as the primary power source.
BCCB conduit boxes must be field installed by a certified electrician.
Floor mount fixture kit is required when floor mounting two or more DK424i cabinets.
Provides two metal stands for mounting any number of DK424i cabinets on floor. Three pairs or
wall brackets (RWBF) are supplied with BFIF to use when mounting three or more DK424i
cabinets on floor. The wall brackets are needed to secure floor-mounted systems to the wall for
safety purposes.
7-6.
(Figure
7-17) and place the cabinet where it should be installed.
(Figures 7-9
and 7-12).
7-54.
Description
(Figure
on
Page
7-6.
(Figure
(Figure
7-5).
Table
7-9.
7-5). Remove plastic locating parts
"Install Power Supply"
"Remote Cabinet Installation
7-8).
Strata DK I&M
6/00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk 424iDk 14Dk 424Dk40iDk 424i

Table of Contents