Table 6-28
Power Cabinet Hardware (continued)
Option
AC208V or AC240VAC nine ft. power supply cord. The cord is rated at 10 amps. (max.) and must
be used when the system is powered by 208VAC or 240VAC. One cord is required for each
cabinet power supply and must be ordered separately only if using 208VAC or 240VAC as the
system primary AC power.
BACL240
Note
The cord is equipped with a 250VAC/20A plug (NEMA 6-20P) which is standard for
240VAC. If using 208VAC as the system primary power this cord may have to be
changed by a certified electrician for one or two cabinet installations. If using three or
more cabinets, a BPSB240 power strip is required and the power strip plug may have to
be changed by a certified electrician depending on local electric codes.
A three-meter long battery cable is used to connect reserve power batteries to the system power
supply when the system has less than three cabinets. One reserve power cable is required for
PBTC-3M
each cabinet in a one or two cabinet system (wall or floor mount). The cable connects the DK424i
cabinet power supply directly to the battery terminals (a BBDB is not required).
DK424i reserve power battery distribution box is required when connecting reserve power
batteries to three or more cabinets (wall or floor mount). The box is field installed into one of the
DK424i cabinet side panels.
BBDB
The BBDB provides seven BBTC2A-2.0M, battery distribution cables to connect reserve power
from the BDDB box to each individual cabinet power supply.
One or two BBTC1A-2.0M must be ordered separately when using the BBDB battery distribution
box.
A two-meter battery cable used to connect reserve power batteries to the BBDB battery
distribution box. One reserve power cable is required in a three or four cabinet system and two
BBTC1A-2.0M
cables are required for five cabinet systems (wall or floor mount). The cable connects DK424i
BBDB box directly to the battery terminals.
DK424i conduit connection box is installed in the bottom cabinet, side panel. It is used to hardwire
Primary AC power and reserve battery power connections through conduit. These boxes are
required by UL for three or more floor mounted cabinets. Conduit boxes are not required for wall
mounted systems with any number of cabinets or floor mounted system with one or two cabinets.
BCCB120 or
They can be used as an option on any system.
BCCB240
The BCCB120 is required when connecting AC120VAC as the primary power source and the
BCCB240 is required when connecting AC208VAC or AC240VAC as the primary power source.
BCCB conduit boxes must be field installed by a certified electrician.
Floor mount fixture kit is required when floor mounting DK424i cabinets.
Provides two metal stands for mounting any number of DK424i cabinets on the floor. Three pairs
BFIF
or wall brackets (RWBF) are supplied with BFIF to use when mounting three or more DK424i
cabinets on floor. The wall brackets are needed to secure floor-mounted systems to the wall for
safety purposes.
Strata DK I&M
6/00
Primary/Reserve Power Cabinet Hardware
Description
DK424i Configuration
6-41