Configurations using analog line circuits are shown in
required for a Remote Maintenance interface PCB with B3CAU/B3CBU and B5CAU/B5CBU;
the Remote Maintenance PCB is optional for B1CU and B2CAU/B2CBU.
Table 6-5
Maximum Configurations Using Analog CO Lines
B1CU
1 Cabinet
8 Universal Slots
56 Stations Max.
32 CO Lines Max.
64 Stations + Analog Lines
Stations
Lines
56
0
56
8*
48
8
48
16*
40
16
40
24*
32
24
32
32*
* Configuration numbers marked with a * do not include a slot for the Remote Maintnenace PCB. All other configurations
(without an *) assume that a slot is available for the Remote Maintenance PCB.
Strata DK I&M
6/00
B2CAU/B2CBU
2 Cabinets
14 Universal Slots
112 Stations Max.
104 CO Lines Max.
112 Stations + Analog Lines
Stations
Lines
112
0*
104
0
104
8*
96
8
96
16*
88
16
88
24*
80
24
80
32*
72
32
72
40*
64
40
64
48*
56
48
56
56*
48
56
48
64*
40
64
40
72*
32
72
32
80*
24
80
24
88*
16
88
16
96*
8
96
8
104*
Table
6-5. One universal slot is always
B3CAU/B3CBU
3 Cabinets
28 Universal Slots
192 Stations Max.
120 CO Lines Max.
216 Stations + Analog Lines
Stations
Lines
192
24
184
32
176
40
168
48
160
56
152
64
144
72
136
80
128
88
120
96
112
104
104
112
96
120
DK424i Configuration
Maximum Station/Line Capacities
B5CAU/B5CBU
5 Cabinets
48 Universal Slots
336 Stations Max.
200 CO Lines Max.
376 Stations + Analog Lines
Stations
Lines
336
40
328
48
320
56
312
64
304
72
296
80
288
88
280
96
272
104
264
112
256
120
248
128
240
136
232
144
224
152
216
160
208
168
200
176
192
184
184
192
176
200