Network Requirements - Toshiba STRATA DK14 Installation And Maintenance Manual

Hide thumbs Also See for STRATA DK14:
Table of Contents

Advertisement

DK424 Installation
Site Requirements

Network Requirements

The system network requirements are provided in
Table 5-3
DK424 Network Requirements
PCB/Interface
PESU/RSTU2/RDSU
(Off-premises Station)
RCOU/RCOS
(loop start line)
RDDU
REMU type 1 or type 2
RGLU2 (ground or loop start
line)
2
RDTU (DS-1/T1)
RCIU2/RCIS (Caller ID)
3
RPTU (PRI)
RBSU/RBSS (S/T, BRI)
RBUU/RBUS (U, BRI)
RCMU/RCMS (CAMA)
1. Only PESU circuits 1 and 2, and RDSU circuits 1~4 provide Off-premises Station (OPS) capability. PESU must use OL13A or
equivalent line conditioning for OPS connection. RDSU must use OL13A or OL13B if providing –24 volt loop voltage. If
equipped with the –48 volt loop option PCB (R48S), OL13A, OL13B, or OL13C may be used for OPS connection.
2. When ordering DS-1/T1 circuits, six items must be specified:
The number of channels per T1 circuit, fractional increments are normally 8, 12, or 16 channels, full service is 24 channels.
Unused channels must be bit-stuffed.
Type of CO line assigned to each channel: Loop Start, Ground Start, Tie (Wink or Immediate Start), DID (Wink or Immediate).
Frame Format Type: Super Frame (SF) or Extended Super Frame (ESF). The T1 provider normally specifies the Frame Format
to be used, either is adequate for DK424 CO digital voice lines. ESF provides a higher level of performance monitoring, but
requires trained personnel and the ESF CSU normally costs more than an SF only CSU.
Line Code Type: Alternate Mark Inversion (AMI) or Bipolar 8 Zero Substitution (B8ZS). The T1 provider normally specified
the Line Code to be used, either is adequate for DK424 T1 CO digital voice lines.
The customer may have to provide the Channel Service Unit (CSU) to interface the DK424 T1 circuit to the Telco T1 circuit.
(CSUs are a Telco requirement.)
RDTU Network Channel Interface Codes: 04DU9-BN, 04DU9-DNZZ, 04DU9-1SN, 04DU9-1KN, 04DU9-1ZN.
3. For information on how to order ISDN PRI/BRI circuits, you should refer to the Toshiba ISDN Training CBT. ISDN circuits
may require a customer-provided CSU for PRI and/or Terminal Adapter or Network Terminal units for BRI. In U.S. CSU/TAs
must be UL-listed in the U.S. In Canada, they must be CSA certified.
Note
5-6
Facility Interface Code
OL13A (PESU)
1
OL13B (RSTU2, –24V)
OL13C (RSTU2, RDSU
with R48S-48V)
02LS2
02RV2-T
TL11M, 2-wire
TL31M, 4-wire
TL12M, type 2, 2-wire
TL32M, type 2, 4-wire
02GS2 (ground)
02LS2 (loop)
(See last bullet note on
Note 2 below.)
N/A
04DU9-1SN
3
02IS5
3
02IS5
02RV2-O
Digital trunks (RDTU, RPTU) may be installed in a Remote Expansion Cabinet; however,
the system can only derive Network Clock Synchronization from digital trunks installed in
a Base Cabinet.
Table
5-3.
Ringer
Network Jack
Equivalence
RJ21X
N/A
RJ14C/RJ21X
0.3B
RJ14C/RJ21X
0.0B
RJ2EX
RJ2GX
Not Available
RJ2FX
(N/A)
RJ2HX
RJ14C/RJ1CX
0.3B
RJ48C/RJ48X/
N/A
RJ48M
RJ21X/RJ14C
0.3B
RJ48C/RJ48M
N/A
RJ48C/RJ48X
N/A
RJ48C/RJ48X
N/A
RJ11C/RJ21-X
N/A
Universal Service
Order Code
9.0F
N/A
AS.2
9.0F
N/A
6.0P
N/A
6.0P
Strata DK I&M
6/00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk 424iDk 14Dk 424Dk40iDk 424i

Table of Contents