Step 5: Install Reserve Power
To BBDB
Battery Distribution Box
Battery Wire Specifications
#10 AWG minimum (2 pairs)
42A max.
Conduit
Holes to 1/2 inch trade size
WARNING!
BCCB conduit boxes must be
installed by a certified electrician.
Figure 7-23 BCCB AC Power and Battery Connections
Notes
When floor mounting the DK424i, the batteries must be installed by a licensed electrician per
G
local electric code using conduit. (See
Batteries should be installed in a customer-supplied commercial battery box or enclosed rack.
G
7-38
F3
F4
F1~F4 Battery
Fuses 250VAC/15A
F3
F4
F1
F2
F1
F2
BCCB
BATT
AC
+
-
L
N
From
From
reserve
20A dedicated
battery
circuit
Figure
7-23.)
BCCB120 (top view)
3 outlets
NEMA:5-15R
Fused: 250VAC/15A
Rated: 125VAC/15A
BCCB240 (top view)
2 outlets
NEMA:6-20R
Not Fused
Rated: 250VAC/20A
AC Wire
Specifications:
BCCB120
5047
#10 AWG
29A max.
BBCB240
#12 AWG
18A max.