DK424 Configuration

Worksheets

Table 4-22
Cabinet Power, Reserve Power, and Floor Mount Hardware Assemblies (continued)
Assembly
RC7C1A-1.7M
RFIF
(up to 7
cabinets)
RCCB1
(up to 6
cabinets)
...or RCCB2
(7 cabinets)
RPSB1
RPSB2
RWBF
Worksheets
The worksheets help you configure the system. Designed to make the system configuration as
orderly as possible, they also provide room to record the hardware - cabinets, PCBs, stations, and
options - that comprise the system.
Copy the worksheets as required, then fill them out in the order they are given.
o
Worksheet 1 – System PCB Slot Requirements
Worksheet 2 – System Cabinet Assignment Guide
o
o
Worksheet 3 – System PCB Assignment Guide
o
Worksheet 4 – Option Configuration Guide
Worksheet 5 – System Power Factor (PF) Check
o
4-20
Description
Used for seven cabinet installations only. Provides long data cable to
Cabinet 7 Cable Kit -
connect the sixth Expansion Cabinet to the DK424 Base Cabinet.
Data and Battery
Provides a long battery cable to connect RBDB2 battery distribution box to
Cables
the sixth Expansion Cabinet power supply.
Provides two metal stands for mounting three or more cabinets on floor.
Floor Mount Fixture
Three pairs of wall brackets (RWBF) are supplied with RFIF. Wall brackets
Kit
are needed to secure floor mounted systems to the wall for safety
purposes (not required to wall mount cabinets).
Conduit box required for AC and battery power connection to three or
more floor-mounted cabinets. (Not required for mounting two cabinets on
a table or any number of cabinets on a wall.)
Conduit Connection
RCCB2 is required instead of RCCB1 for seven cabinet floor mount
Box
installations.
A licensed electrician must install this item to retain UL listing and/or local
electrical code compliance.
One RPSB1 required when installing three or four cabinets (wall or floor
mount).
Three-outlet AC
Power Strip
Two RPSB1s required when installing five, six, or seven cabinets (wall or
floor mount). Two AC cords will exit the cabinets in some configurations.
High current carrying capacity cord for application where local electric
Three-outlet AC
codes (or user) requires only one AC cord to exit four or more cabinets. It
Power Strip - heavy
is highly recommended to use the RPSB2 for two-cabinet installations to
cord
accommodate further growth. Must be ordered for seven cabinet systems.
Required for seven cabinet systems when the system is floor mounted.
Wall bracket pair
Secures the seventh cabinet to the wall for safety purposes (not required
to wall mount cabinets – see RFIF).
Function
Strata DK I&M
6/00