Night Transfer/Night Relay Options With Piou, Pious, Or Pepu - Toshiba STRATA DK14 Installation And Maintenance Manual

Hide thumbs Also See for STRATA DK14:
Table of Contents

Advertisement

Peripheral Installation
Relay Control Options and Door Lock Control
DK14 KSU,
DK40i KSU,
PDKU,
RDSU,
PEKU,
or
PESU
PEKU or PESU
VT (34) / VR (9)
DT (35) / DR (10)
Notes
1. Relay control contact will close when the door phone is in the ringing, talk, or monitor state.
2. See External Page/Door Lock Relay Options on Page 10-14 and DDCB and HDCB/DRLK
3. Relay contact specifications are -24VDC at 1.0 amp. max. Do not connect relay contacts to 120
Figure 12-10 Multiple Door Lock Control Options (DDCB/HDCB)

Night Transfer/Night Relay Options with PIOU, PIOUS, or PEPU

Night Transfer/Night Relay option may be programmed for either the Night Relay or the MOH
relay function. (See
Note
When configured for the NT function with Program 77-1, the relay activates if the system is in the
Night mode. The relay can be programmed to activate continuously when the
button (only) is set for the Night mode (for indirect answering machine control), or to pulsate at
one-second On/three-seconds Off (for a night bell) when incoming CO lines ring (Night Transfer
1~4 = tenant 1~4 CO lines) per Program *15 and 77-3.
When configured for the MOH function with Program 77-1, the relay activates any time a CO line
is on hold. In this configuration, the relay is normally used to control the MOH source.
12-16
DDCB or HDCB
Relay
Control
Contact
1
(See Chapter 8—
Wiring Diagrams)
DK14 (Ports 002, 003)
DK40i/DK424 (Ports 004,
012, 020)
DK424 (Port 028)
Door Lock
Control
2
Contact
HDCB WIRING CHART
to
HDCB KSU Jack
to
PIN 3 / 4
to
PIN 5 / 6
See Chapter 8—Wiring for PEKU, PESU, PDKU or RDSU pin-out information.
See DK14 and DK40i Installation chapters for appropriate pin-out information.
Assignments Guide on Page 10-19.
AC commercial power.
Figures 12-7
Only the PIOU/PIOUS, or PEPU with the lowest Program 03 code (41, 42 or 43) will
provide the Night Transfer (NT) or MOH relay control function.
RJ11
A
2
3
3
4
Relay Contact
4
2
to Customer
5
5
Supplied
B
RJ11
Device
3
3
4
4
C
RJ11
3
3
4
4
PDKU or RDSU
DT (34) / DR (9)
PT (35) / PR (10)
and 12-8.)
MDFB
1
2
Door Phone
A
3
MDFB
1
Door Phone B
or
Door Lock Control
2
MDFB
1
Door Phone
C
2
DDCB Wiring Chart
to
DDCB KSU Jack
to
PIN 3 / 4
to
PIN 5 / 6
1LJKW 7UDQVIHU
Strata DK I&M
4301
6/00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk 424iDk 14Dk 424Dk40iDk 424i

Table of Contents