DK424 Installation
Reserve Power Installation
CAB 1
2043
Important!
Figure 5-21 AC Power Distribution for Six Cabinets
5-36
RPSU280A
MBJU
(see Note below)
AC IN
Jumper Unit
FG
RPSU280A
Frame Ground
Screw (FG)
AC IN
Data Cables
FG
CAB 2
RPSU280A
AC IN
FG
CAB 3
RPSU280A
AC IN
FG
CAB 4
RPSU280A
AC IN
FG
CAB 5
RPSU280A
AC IN
FG
CAB 6
Remove MBJU only when RCTUE/F is installed.
ONEAC 6-AP
or 6-DP
Solid State
Secondary
Protectors
Insulated
Ground
Wire "B"
Cold Water Pipe
Or Ground Rod
Earth Ground:
Per General Rules of Article 250 Of
The National Electric Code,
NFPA70
Third Wire
AC Ground
Building Main Power
Panel Electrical Ground
115VAC ±10VAC (50/60 Hz)
Dedicated 15 Amp
Branch Circuit
115VAC ± 10VAC (50/60 Hz)
(11.5 Amp max)
Third Wire Ground
AC Cable
to AC Power
Intercabinet Power
Supply Ground Wire
AWG #6 Wire
Maximum
Length: 60 Feet
"A"
Strata DK I&M