Station Apparatus
Direct Station Selection (DSS) Console/System Connection
Standard twisted single-pair or two-pair jacketed telephone cable (maximum 1000 feet, 303
meters) is used for the connection.
To accommodate the DDSS console connection, the instrument end of the cable should be
terminated in a modular station connector block (RJ11). Refer to
Wiring
for wiring/interconnecting details.
Notes
DDSS console cable runs must not have cable splits (single or double), cable bridges (of any
G
length) or high resistance or faulty cable splices.
See the appropriate Installation chapter for secondary protection information and loop limits.
G
CAUTION!

DDSS Console Configuration

An RDSU will not support a DDSS.

DDSS Programming

Program 03: Code 64 identifies the slots that support DDSS consoles.
Program 28: Assigns DDSS console(s) to telephones.
Program 29: Assigns button functions for DDSS consoles.

HDSS Console

HDSS Console Connections
The HDSS console must be connected to the data pairs of circuits 7 and 8 on a PEKU with
standard two-pair twisted, jacketed telephone cable. To accommodate the connection, the
instrument end of the HDSS console cable should be terminated in a modular station connector
block (RJ11). Refer to
If using 24 AWG cable, the overall length of the cable run from the Expansion Unit (KSU) to the
HDSS console must not exceed 500 feet (152 meters). The HDSS console can operate with either
an electronic or digital telephone (preferably an LCD model).
CAUTION!
11-28
When installing the DDSS cable, do not run the cables parallel if they are
within three feet of an AC power line. AC power lines should be crossed at right
(90
) angles only. In particular, avoid running station wire pairs near devices
°
that generate electrical noise, such as neon or fluorescent light fixtures.
Chapter 10 – Universal Slot PCB Wiring
When installing the HDSS console cable, do not run the cables parallel if they
are within three feet of an AC power line. AC power lines should be crossed at
right (90
) angles only. Avoid running HDSS console wire pairs near devices
°
that generate electrical noise, such as neon or fluorescent light fixtures.