DK424i Installation
Step 4: Install AC Power Components
One cabinet - one AC cord exits system
Cabinet 1
Front
Two cabinets - two AC cord exit system
Cabinet 1
Cabinet 2
Four or five cabinets - two AC cords exit system
Cabinet 1
Cabinet 2
Cabinet 3
Cabinet 4
Cabinet 5
Notes
1. 120VAC cord is supplied with cabinet. A special cord, BACL240, must be ordered for
each cabinet if 208VAC or 240VAC is used.
2. Power Strips must plug into the following AC outlets: 120VAC to NEMA 5-15R, and
208/240VAC to NEMA 6-20R.
Figure 7-14 AC Power Cords in Cabinets
7-24
Right-side
Power
Supply
panel
Notes 1, 2
(120/208/240VAC)
Power
Supply
Note 2
(120VAC only)
Power
Supply
Note 2
(120VAC only)
Power
Supply
Power
Supply
Power
RPSB2
Supply
Note 2
(120VAC only)
Power
Supply
RPSB2
Notes 1, 2
Power
(120VAC only)
Supply
Two or three cabinets - one AC cord exits system
Cabinet 1
Power
Supply
Cabinet 2
Power
Supply
Cabinet 3
Power
Supply
Four or five cabinets - one AC cord exits system
Cabinet 1
Power
Supply
Cabinet 2
Power
Supply
Cabinet 3
Power
Supply
Cabinet 4
Power
Supply
Cabinet 5
Power
Supply
BPSB240
(208/240VAC)
or
RPSB2
(120VAC)
Notes 1, 2
(120/208/240VAC)
BPSB240
BPSB240
Notes 1, 2
(208VAC
or 240VAC only)
5033