Replacing The Air Baffle - Lenovo System x3250 M5 Installation And Service Manual

Hide thumbs Also See for System x3250 M5:
Table of Contents

Advertisement

Figure 71. PCI riser-card assembly installation
Step 4.
Reinstall the cover (see "Replacing the cover" on page 80).
What to do next
1. Install the server into the rack enclosure and push the server into the rack until it clicks into place.
2. Reconnect the power cords and any cables that you removed.
3. Turn on the peripheral devices and the server.

Replacing the air baffle

Use this information to replace the air baffle.
Read the safety information in "Safety" on page v and "Installation guidelines" on page 31.
If you are replacing a server component in the server, you need to slide the server out from the rack
enclosure, turn off the server and peripheral devices, and disconnect the power cords and all external cables.
To replace the air baffle, complete the following steps.
Step 1.
Align the air baffle pins with the baffle pin holes on the server chassis and fan cage assembly; then,
lower the air baffle into the server. Press the air baffle down until it is securely seated.
.
Chapter 2
Installing optional devices
79