Lenovo System x3250 M5 Installation And Service Manual page 468

Hide thumbs Also See for System x3250 M5:
Table of Contents

Advertisement

2. Make sure that ambient temperature is within the specifications.
3. If a fan has failed, complete the action for a fan failure.
4. Replace DIMM n. (n = DIMM number)
806f0a0c-2004ffff : An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 4)
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
May also be shown as 806f0a0c2004ffff or 0x806f0a0c2004ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air
baffles are in place and correctly installed, and that the server cover is installed and completely
closed.
2. Make sure that ambient temperature is within the specifications.
3. If a fan has failed, complete the action for a fan failure.
4. Replace DIMM n. (n = DIMM number)
• 81010002-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower non-critical)
has deasserted. (CMOS Battery)
This message is for the use case when an implementation has detected a Lower Non-critical sensor
going low has deasserted.
May also be shown as 810100020701ffff or 0x810100020701ffff
Severity
Info
Serviceable
454