Read the safety information in "Safety" on page v and "Installation guidelines" on page 31.
If you are installing an optional device in the server, you need to slide the server out from the rack enclosure,
turn off the server and peripheral devices, and disconnect the power cords and all external cables.
Note: For brevity, in this documentation the Lenovo ServeRAID SAS/SATA controller is often referred to as
the SAS/SATA adapter or the ServeRAID adapter.
To install an optional ServeRAID SAS/SATA controller memory module, complete the following steps.
Step 1.
Remove the cover (see "Removing the cover" on page 33).
Step 2.
Remove the PCI riser-card assembly (see "Removing the PCI riser-card assembly" on page 163).
Step 3.
Remove the ServeRAID SAS/SATA controller if necessary ( "Removing an Lenovo ServeRAID
SAS/SATA controller" on page 187).
Step 4.
Touch the static-protective package that contains the memory card to any unpainted metal surface
on the server; then, remove the memory card from the package.
Step 5.
Align the memory module with the connector on the ServeRAID SAS/SATA controller and push
it into the connector until it is firmly seated.
Figure 61. ServeRAID SAS/SATA controller memory module installation
Step 6.
Reinstall the ServeRAID SAS/SATA controller ( "Installing an Lenovo ServeRAID SAS/SATA
controller" on page 61).
Step 7.
Reinstall the PCI riser-card assembly (see "Replacing the PCI riser-card assembly" on page 78).
If you have other devices to install, do so now. Otherwise, go to "Completing the installation" on page 78.

Installing a RAID adapter battery or flash power module

Use this information to install a RAID adapter battery or flash power module in the server.
When you install any RAID adapter that comes with batteries or flash power modules, it is sometimes
necessary to install the batteries or flash power modules in another location in the server to prevent the
batteries or flash power modules from overheating. Depending on your server model, a battery must be
installed remotely near the optical drive cage or the backplane.
Note: RAID adapter battery or flash power module is only supported in the 2.5-inch models.