CIM Information
Prefix: PLAT ID: 0530
User Response
If the specified sensor is PS n 12V OC Fault, complete the following steps until the problem is solved:
1.
Use the IBM Power Configurator utility to determine current system power
consumption. For more information and to download the utility, go to
http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html.
2. Follow actions in "Power Problems and Solving Power Problems".
If the specified sensor is PS n 12V OV Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. (Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12V UV Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. Follow actions in "Power Problems and Solving Power Problems".
4. (Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12Vaux Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Replace power supply n. (n = power supply number)
• 80070614-2201ffff : Sensor [SensorElementName] has transitioned to non-recoverable. (TPM Phy
Pres Set)
This message is for the use case when an implementation has detected a Sensor transitioned to
non-recoverable.
May also be shown as 800706142201ffff or 0x800706142201ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0530
User Response
1. Update the server firmware (see Recovering the server firmware).
Appendix A. Integrated Management Module II (IMM2) error messages
377