Figure 101. 2.5-inch hot-swap hard disk drive installation
Figure 102. 3.5-inch hot-swap hard disk drive installation
c.
Gently push the drive into the bay until the drive stops.
d.
Rotate the tray handle to the closed (locked) position.
e.
Check the hard disk drive status LED to verify that the hard disk drive is operating correctly. If
the yellow hard disk drive status LED of a drive is lit continuously, that drive is faulty and must
be replaced. If the green hard disk drive activity LED is flashing, the drive is being accessed.
Note: If the server is configured for RAID operation using a ServeRAID adapter, you might
have to reconfigure your disk arrays after you install hard disk drives. See the ServeRAID
adapter documentation for additional information about RAID operation and complete
instructions for using the ServeRAID adapter.
Step 4.
If you are installing additional hot-swap hard disk drives, do so now.
Removing a simple-swap hard disk drive
Use this information to remove a simple-swap hard disk drive.
.