Lenovo System x3250 M5 Installation And Service Manual page 403

Hide thumbs Also See for System x3250 M5:
Table of Contents

Advertisement

40
CIM Information
Prefix: PLAT ID: 0850
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Recover the server firmware from the backup page: a. Restart the server. b. At the prompt,
press F3 to recover the firmware.
3. Update the server firmware to the latest level (see Updating the firmware). Important: Some
cluster solutions require specific code levels or coordinated code updates. If the device is part
of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
4. Remove components one at a time, restarting the server each time, to see if the problem
goes away.
5. If the problem remains, (trained service technician) replace the system board.
Firmware Error : Sys Boot Status :
• 806f000f-22010cff : CPU voltage mismatch detected on [ProcessorElementName]. (ABR Status)
This message is for the use case when an implementation has detected a CPU voltage mismatch with the
socket voltage.
May also be shown as 806f000f22010cff or 0x806f000f22010cff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0050
User Response
This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged
IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section
of the Info Center for the appropriate user response. Firmware Error : Sys Boot Status :
• 806f000f-2201ffff : The System [ComputerSystemElementName] encountered a POST Error. (ABR
Status)
This message is for the use case when an implementation has detected a Post Error.
Appendix A. Integrated Management Module II (IMM2) error messages
389

Advertisement

Table of Contents
loading

Table of Contents