Lenovo System x3250 M5 Installation And Service Manual page 685

Hide thumbs Also See for System x3250 M5:
Table of Contents

Advertisement

202-000-000 : MemStr Test Passed
Test Passed.
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
IBM Support website
Latest level of DSA
Latest level of BMC/IMM
202-801-000 : MemStr Test Aborted
Internal program error.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Turn off and restart the system.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Run the test again.
4. If the system has stopped responding, turn off and restart the system.
5. Check the system firmware level and upgrade if necessary.
6. Run the memory diagnostic to identify the specific failing DIMM.
7. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and
Service Guide" for the next corrective action.
Related links
IBM Support website
Latest level of DSA
Latest level of BMC/IMM
Appendix C. DSA diagnostic test results
671

Advertisement

Table of Contents
loading

Table of Contents