• S.3060007 [S.3060007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check IBM Support website for an applicable service bulletin or firmware update that applies to
this error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
• S.3070007 [S.3070007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check IBM Support website for an applicable service bulletin or firmware update that applies to
this error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
• S.3108007 [S.3108007 ] The default system settings have been restored.
Explanation: System Configuration Restored to Defaults
Severity
Error
User Response
Complete the following steps:
1. Check IBM Support website for an applicable service bulletin or firmware update that applies to
this error.
S.3818004 [S.3818004] The CRTM flash driver could not successfully flash the staging area. A
failure occurred.
Explanation: CRTM Update Failed
Severity
Error
User Response
Complete the following steps:
1. Continue booting sytem. If system does not reset, manually reset the system.
Appendix B. UEFI (POST) error codes
539