3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
•
806f070c-2001ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 1)
This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
May also be shown as 806f070c2001ffff or 0x806f070c2001ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
•
806f070c-2002ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 2)
This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
May also be shown as 806f070c2002ffff or 0x806f070c2002ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
Appendix A. Integrated Management Module II (IMM2) error messages
439