Explanation: IPMI System Event Log is Full
Severity
Info
User Response
Complete the following steps:
1. Use IMM Web Interface to clear event log.
2. If IMM communication is unavailable, use F1 Setup to access System Event Logs Menu and
Choose Clear IMM System Event Log and Restart Server.
• I.3818001 [I.3818001] The firmware image capsule signature for the currently booted flash bank
is invalid.
Explanation: Current Bank CRTM Capsule Update Signature Invalid
Severity
Info
User Response
Complete the following steps:
1. Reboot system. Will come up on backup UEFI image. Reflash the primary UEFI image.
2. If error does not persist no additional recovery action is required.
3. If error persists, or boot is unsuccessful, (trained service technician only) replace the system
board.
I.3818002 [I.3818002] The firmware image capsule signature for the non-booted flash bank is
invalid.
Explanation: Opposite Bank CRTM Capsule Update Signature Invalid
Severity
Info
User Response
Complete the following steps:
1. Reflash backup UEFI image.
2. If error does not persist no additional recovery action is required.
3. If error persists, or boot is unsuccessful, (trained service technician only) replace the system
board.
• I.3818003 [I.3818003] The CRTM flash driver could not lock the secure flash region.
Explanation: CRTM Could not lock secure flash region
Severity
Info
User Response
Complete the following steps:
1. If system failed to boot successfully, DC cycle system.