Lenovo System x3250 M5 Installation And Service Manual page 420

Hide thumbs Also See for System x3250 M5:
Table of Contents

Advertisement

Automatically notify support
No
Alert Category
System - Boot failure
SNMP Trap ID
25
CIM Information
Prefix: PLAT ID: 0186
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Update the server firmware on the primary page. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
3. (Trained technician only) Replace the system board.
806f0123-2101ffff : Reboot of system [ComputerSystemElementName] initiated by
[WatchdogElementName]. (IPMI Watchdog)
This message is for the use case when an implementation has detected a Reboot by a Watchdog occurred.
May also be shown as 806f01232101ffff or 0x806f01232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0370
User Response
No action; information only.
• 806f0207-0301ffff : [ProcessorElementName] has Failed with FRB1/BIST condition. (CPU 1)
This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST
condition.
May also be shown as 806f02070301ffff or 0x806f02070301ffff